Market Notices

144144RECLASSIFY CONTINGENCY25/05/2026 10:59:35 PM

Cancellation of a Non-Credible Contingency Event: Penola West - South East 1 132kV line and Kincraig - Penola West 1 132kV line in SA1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: SA1

Lines: Penola West - South East 1 132kV and Kincraig - Penola West 1 132kV

Cancellation time: 25/05/2026 22:59

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 144143

Auto-generated on behalf of Manager NEM Real Time Operations
     
144143RECLASSIFY CONTINGENCY25/05/2026 08:55:51 PM

Reclassification of a Non-Credible Contingency Event: Penola West - South East 1 132kV line and Kincraig - Penola West 1 132kV line in SA1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: SA1

Lines: Penola West - South East 1 132kV and Kincraig - Penola West 1 132kV

Duration: 25/05/2026 20:55 until further notice

Constraint set(s) invoked:
NONE

Auto-generated on behalf of Manager NEM Real Time Operations
     
144142CONSTRAINTS25/05/2026 02:50:50 PM

Updated system normal constraints to manage Murraylink dynamic rating forecast in pre-dispatch and PASA

Refer to Market Notice 134696

AEMO has now completed the production of the Murraylink dynamic rating forecast model and the forecasting performance has been satisfactory during the test. AEMO will be enabling the pre-dispatch and PASA formulation using the Murraylink dynamic rating forecast on the following two constraint equations at 1000 hrs on Wednesday 27th May 2026.

VSML_RAT_LIM_DYN
SVML_RAT_LIM_DYN

For full details on the formulation, the updated constraint equations have now been loaded into AEMO's pre-production systems.

Terry Liu
AEMO Operations
     
144125RECLASSIFY CONTINGENCY20/05/2026 10:44:50 PM

Cancellation of a Non-Credible Contingency Event: Mudgeeraba - Terranora No.757 110 kV line and Mudgeeraba - Terranora No.758 110 kV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Mudgeeraba - Terranora No.757 110 kV and Mudgeeraba - Terranora No.758 110 kV

Cancellation time: 20/05/2026 22:44

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 144123

Auto-generated on behalf of Manager NEM Real Time Operations
     
144123RECLASSIFY CONTINGENCY20/05/2026 08:39:25 PM

Reclassification of a Non-Credible Contingency Event: Mudgeeraba - Terranora No.757 110 kV line and Mudgeeraba - Terranora No.758 110 kV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Mudgeeraba - Terranora No.757 110 kV and Mudgeeraba - Terranora No.758 110 kV

Duration: 20/05/2026 20:39 until further notice

Constraint set(s) invoked:
NONE

Auto-generated on behalf of Manager NEM Real Time Operations
     
144114RESERVE NOTICE18/05/2026 10:16:42 AM

PDPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the QLD Region on 18/05/2026

AEMO ELECTRICITY MARKET NOTICE

The Forecast LOR1 condition in the QLD region advised in AEMO Electricity Market Notice No. 144111 is cancelled at 1015 hrs 18/05/2026.

Manager NEM Real Time Operations
     
144111RESERVE NOTICE17/05/2026 08:20:51 PM

PDPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the QLD Region on 18/05/2026

AEMO ELECTRICITY MARKET NOTICE

The Forecast LOR1 condition in the QLD region advised in AEMO Electricity Market Notice No. 144108 has been updated to the following:

[1.] From 1700 hrs 18/05/2026 to 1900 hrs 18/05/2026.
The forecast capacity reserve requirement is 1194 MW.
The minimum capacity reserve available is 1014 MW.

Manager NEM Real Time Operations
     
144109RESERVE NOTICE17/05/2026 02:34:41 PM

ST PASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the QLD Region on 19/01/2026

AEMO ELECTRICITY MARKET NOTICE

The Forecast LOR1 condition in the QLD region advised in AEMO Electricity Market Notice No. 144092 has been updated to the following:

[1.] From 0600 hrs 19/05/2026 to 1930 hrs 19/05/2026.
The forecast capacity reserve requirement is 1197 MW.
The minimum capacity reserve available is 1012 MW.

[2.] From 2130 hrs 19/05/2026 to 2200 hrs 19/05/2026.
The forecast capacity reserve requirement is 1199 MW.
The minimum capacity reserve available is 1146 MW.


Manager NEM Real Time Operations
     
144108RESERVE NOTICE17/05/2026 02:20:46 PM

PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the QLD Region on 18/05/2026

AEMO ELECTRICITY MARKET NOTICE

AEMO declares a Forecast LOR1 condition under clause 4.8.4(b) of the National Electricity Rules for the QLD region for the following Periods:


[1.] From 1700 hrs 18/05/2026 to 1930 hrs 18/05/2026.
The forecast capacity reserve requirement is 1194 MW.
The minimum capacity reserve available is 829 MW.


[2.] From 2200 hrs 18/05/2026 to 2230 hrs 18/05/2026.
The forecast capacity reserve requirement is 1197 MW.
The minimum capacity reserve available is 1194 MW.


Manager NEM Real Time Operations
     