Update to NEM load table (Unmetered Loads) – current proposals

Proposal to Update NEM Load Table (Unmetered Loads)

Following the migration from the Jurisdictional Metrology Procedures to the NEM Metrology Procedure, the obligation to update and publish the Load Tables for Type 7 Metering Installations (NEM Load Table) lies with AEMO.

The NEM Load Table sets out the power consumption values for each unmetered device type.  These power consumption values are used in the algorithm that calculates metering data for unmetered loads in the NEM.

As per clause 12.1.4(d) of the NEM Metrology Procedure Part B AEMO is required to:

  • Consider and publish proposals to add an unmetered device type to the NEM Load Table.
  • Take into account the views of interested parties to determine whether to add an unmetered device type to the NEM Load Table.

The following process will be used to amend the NEM Load Table:

  • Publish the supporting documentation for the proposed new unmetered device load value on the AEMO website for comment and agreement by industry.
  • Period for comments on the proposed unmetered device load value will be 20 business days.
  • In the absence of any comments that dispute these proposals, AEMO will take the proposed load for the unmetered device type as agreed.
  • The new unmetered device load value agreed and published in the NEM Load Table may only be used exactly as tested.
  • The new unmetered device load value agreed and published can be used in all NEM jurisdictions that have declared street lights as market loads.

AEMO invites comment as to the acceptance of this new unmetered device load value into the NEM Load Table as per clause 12.1.4(d) of the NEM Metrology Procedure Part B.


Sylvania-Schreder Avenue MK3 LED Luminaires ()

Sylvania-Schreder has applied to have its Muro Branco LED Luminaires added to the NEM Load Table as unmetered devices and has proposed the following amendment to the NEM Load Table:

Jurisdiction Submitted by
Unmetered Device
Load as tested (W)
ALL Sylvania-Schreder Avenue MK3 14W 13.8
ALL Sylvania-Schreder Avenue MK3 18W 17.9

AEMO has considered the Sylvania-Schreder proposal against the minimum requirements to add new unmetered device types to the NEM Load Table (as set out in clause 12.1.4(d) of the Metrology Procedure Part: B) and concludes that this proposal fulfils these minimum requirements.

The Sylvania-Schreder proposal, including supporting test results, technical summary and letter from Energy Queensland supporting the installation of this device are published on this web page.

Please direct all comments to David Ripper, Principal Metrology Engineer, [email protected]

Date of publication: 4 June 2026.

Responses to be submitted by no later than 3 July 2026.

Signify Australia Tango Pro BVP LED Luminaires (3)

Signify Australia has applied to have its Tango BVP LED Floodlights added to the NEM Load Table as an unmetered device and has proposed the following amendment to the NEM Load Table:

Jurisdiction Submitted by
Unmetered Device
Load as tested (W)
ALL Signify Australia Tango Pro BVP561 LED91/740 53W FP AMB P7 ANZ Luminaire 52.6W
ALL Signify Australia Tango Pro BVP561 LED156/740 97W FP AMB P7 ANZ Luminaire 96.0W
ALL Signify Australia Tango Pro BVP564 LED230/NW 130W FP AMB P7 ANZ Luminaire 127.2W

AEMO has considered the Signify Australia proposal against the minimum requirements to add new unmetered device types to the NEM Load Table (as set out in clause 12.1.4(d) of the Metrology Procedure Part: B) and concludes that this proposal fulfils these minimum requirements.

The Signify Australia proposal, including supporting test results, technical summary and letter from Ausgrid supporting the inclusion of this device are published on this web page.

Please direct all comments to David Ripper, Principal Metrology Engineer, [email protected]

Date of publication: 21 May 2026.

Responses to be submitted by no later than 19 June 2026.

Aldridge Boston III 20W LED Luminaire

Aldridge Traffic Systems has applied to have its Boston III 20W LED Luminaire added to the NEM Load Table as unmetered devices and has proposed the following amendment to the NEM Load Table:

Jurisdiction Submitted by
Unmetered Device
Load as tested (W)
ALL Aldridge Traffic Systems Boston III 20W 20W

AEMO has considered the Aldridge proposal against the minimum requirements to add new unmetered device types to the NEM Load Table (as set out in clause 12.1.4(d) of the Metrology Procedure Part: B) and concludes that this proposal fulfils these minimum requirements.

The Aldridge proposal, including supporting test results, technical summary and letter from Queensland Rail supporting the installation of this device are published on this web page.

Please direct all comments to David Ripper, Principal Metrology Engineer, [email protected]

Date of publication: 14 May 2026.

Responses to be submitted by no later than 12 June 2026.