144055RECLASSIFY CONTINGENCY06/05/2026 04:24:21 PM

Cancellation of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV

Cancellation time: 06/05/2026 16:24

Constraint set(s) revoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1


Refer AEMO Electricity Market Notice 144054

Auto-generated on behalf of Manager NEM Real Time Operations
     
144054RECLASSIFY CONTINGENCY06/05/2026 03:21:46 PM

Reclassification of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: NSW1

Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV

Duration: 06/05/2026 15:21 until further notice

Constraint set(s) invoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1


Auto-generated on behalf of Manager NEM Real Time Operations
     
144053POWER SYSTEM EVENTS06/05/2026 01:21:48 PM

Non-credible contingency event - QLD region - 6/05/2026

AEMO ELECTRICITY MARKET NOTICE.

Non-credible contingency event - QLD region - 6/05/2026

At 1239 hrs the Townsville South No. 2 132 kV Bus tripped.

AEMO did not instruct load shedding.

AEMO has not been advised of any disconnection of bulk electrical load.

The cause of this non credible contingency event has been identified and AEMO is satisfied that another occurrence of this event is unlikely under the current circumstances.

AEMO will not reclassify this event as a credible contingency event.


Manager NEM Real Time Operations
     
144052MARKET INTERVENTION06/05/2026 01:02:31 PM

Cancellation - AEMO Intervention Event - SA region 6/05/2026

AEMO ELECTRICITY MARKET NOTICE

Cancellation - AEMO Intervention Event - SA region 06/05/2026

Refer to Market Notice 144049

The AEMO Intervention Event and all associated directions are cancelled from 1300 hrs on 6/05/2026.


Manager NEM Real Time Operations
     
144051MARKET INTERVENTION06/05/2026 01:01:55 PM

Cancellation: Direction issued to: Origin Energy Electricity Limited - QUARANTINE PS UNIT 5

AEMO ELECTRICITY MARKET NOTICE

Cancellation: Direction issued to: Origin Energy Electricity Limited - QUARANTINE PS UNIT 5

Refer to Market Notice 144050

Direction is cancelled from: 1300 hrs 6/05/2026

Manager NEM Real Time Operations
     
144050MARKET INTERVENTION06/05/2026 10:16:59 AM

Direction - in SA region to Origin Energy Electricity Limited - QUARANTINE PS UNIT 5

AEMO ELECTRICITY MARKET NOTICE

Direction - in SA region to Origin Energy Electricity Limited - QUARANTINE PS UNIT 5

Refer to Market Notice 144048.


In accordance with section 116 of the National Electricity Law, AEMO is issuing a direction to Origin Energy Electricity Limited. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).

Direction issued to: Origin Energy Electricity Limited - QUARANTINE PS UNIT 5 at 1015 hrs 6/05/2026
Type of resource: generating unit
Required actions: Synchronise and follow dispatch targets at 1100 hrs 6/05/2026
Services provided: Voltage Control
Circumstances necessitating the Direction: Voltage
Circumstances necessitating the Direction additional detail: The synchronous generating units currently expected to be synchronised in SA will be inadequate to maintain sufficient Voltage Control in SA. Intervention is required to maintain the power system in a secure operating state
Expected duration: 1300 hrs 6/05/2026.

Origin Energy Electricity Limited does not incur any civil monetary liability for a relevant action taken in accordance with this direction unless the action is taken in bad faith.

Manager NEM Real Time Operations
     
144049MARKET INTERVENTION06/05/2026 10:17:33 AM

Direction - SA region 6/05/2026

AEMO ELECTRICITY MARKET NOTICE

Direction - SA region 6/05/2026

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).

The issue of the direction commences an AEMO intervention event. AEMO declares all trading intervals during the event to be intervention trading intervals, commencing from the interval ending 1105 hrs on 6/05/2026.

Intervention pricing does not apply to this AEMO intervention event.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.


Manager NEM Real Time Operations
     
144048MARKET INTERVENTION05/05/2026 07:30:57 PM

Foreseeable AEMO intervention in SA region

Foreseeable AEMO intervention in SA region

AEMO has identified a foreseeable circumstance that may require an AEMO intervention event in the SA region from 1100 hrs 06/05/2026.

The foreseeable circumstance requiring the need for intervention is Voltage.

AEMO estimates that, in the absence of sufficient market response by 1015 hrs 06/05/2026, AEMO may need to intervene by issuing a direction.

Manager NEM Real Time Operations
     
144047INTER-REGIONAL TRANSFER05/05/2026 02:30:24 AM

Inter-Regional Transfer limit variation - Directlink - NSW Region

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Directlink - NSW Region

There has been an unplanned outage of the No 3 Leg of Directlink .

The following constraint set was invoked at 0230hrs 05/05/2026

N-MBTE_1

The constraint set contains the following interconnector on the left hand side.

N-Q-MNSP1

Refer AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
     